Kernel : 2.6.32-358.el6.x86_64<br />
NIC : Broadcom Corporation NetXtreme II BCM5709S Gigabit Ethernet<br />
bnx2i driver version : 2.7.2.2<br />
<br />
<br />
rootvgpv01 (36090a08820e5e9e536207594cacb4d81) dm-0 EQLOGIC,100E-00<br />
size=25G features='0' hwhandler='0' wp=rw<br />
`-+- policy='round-robin 0' prio=1 status=active<br />
|- 4:0:0:0 sdc 8:32 active ready running (<-- connected ia tcp)<br />
`- 0:0:0:0 sde 8:64 failed faulty running (<-- connected by TOE)<br />
<br />
<br />
Aug 10 12:26:43 mt0dbprd1 iscsid: Kernel reported iSCSI connection 3:0 error (1011 - ISCSI_ERR_CONN_FAILED: iSCSI connection failed) state (3)<br />
Aug 10 12:26:46 mt0dbprd1 kernel: connection3:0: detected conn error (1011)<br />
Aug 10 12:26:47 mt0dbprd1 kernel: connection3:0: bnx2i: conn update - MBL 0x40000 FBL 0x10000MRDSL_I 0x40000 MRDSL_T 0x10000 <br />
Aug 10 12:26:47 mt0dbprd1 iscsid: connection3:0 is operational after recovery (1 attempts)<br />
Aug 10 12:26:48 mt0dbprd1 kernel: connection3:0: bnx2i: iscsi_error - ERL0, UO<br />
Aug 10 12:26:48 mt0dbprd1 kernel: connection3:0: conn_err - hostno 0 conn ffff880428b82480, iscsi_cid 63 cid 13b000<br />
Aug 10 12:26:48 mt0dbprd1 kernel: connection3:0: detected conn error (1011)<br />
Aug 10 12:26:48 mt0dbprd1 multipathd: rootvgpv01: sde - readsector0 checker reports path is down<br />
10 12:26:48 mt0dbprd1 iscsid: Kernel reported iSCSI connection 3:0 error (1011 - ISCSI_ERR_CONN_FAILED: iSCSI connection failed) state (3)
↧